Btw. ked sme pri tom - ked mam 9kW spotrebic na troch fazach, je to 13A alebo 7,5A na fazu?

Zalezi na tom ci je zataz symetricka a ci je spotrebic zapojeny do hviezdy alebo do trojuholnika.

Vo hviezde to bude na napati 230 V a bude tam prud 13A.
V trojuholniku to bude 7.5A




000001010006354000957917092626020926260309262606
mysak
 mysak      02.09.2025 - 18:31:05 , level: 1, UP   NEW
saunova piecka - teda asi rovnomerna odporova zataz na 3f
netusim, ci to je hviezda alebo trojuholnik :)

00000101000635400095791709262602092626030926260609262614
akira
 akira      02.09.2025 - 18:47:47 , level: 2, UP   NEW
Ta sauna nema instalacny navod ?

0000010100063540009579170926260209262603092626060926261409262630
mysak
 mysak      02.09.2025 - 20:39:16 , level: 3, UP   NEW
bude ju instalovat firma, ja mam pripravit pripojku
udaj, ktory mam, je 9kW, 3f, 5x2,5 CYKY (davam 4, mam to daleko), prudovy chranic a istic

000001010006354000957917092626020926260309262606092626140926263009262635
akira
 akira      02.09.2025 - 21:08:25 , level: 4, UP   NEW
Ak to bude daky seriovo vyrabany typ, tak to ma instalacny navod, vygoogli si ho, a tam najdes nahrubo schemu zapojenia.

A podla toho aky budes mat istic, to by mala vydrzat instalacia bez ohladu na to ze k nej bude prave pripojena sauna XY. Ak mas 3x16A tak by ten obvod mal byt stavany na odber 3x16A.